Intraocular lens power calculation in keratoconus; a review of literature

Ghiasian, L. and Abolfathzadeh, N. and Manafi, N. and Hadavandkhani, A. (2019) Intraocular lens power calculation in keratoconus; a review of literature. Journal of Current Ophthalmology.

[img]
Preview
Text
Intraocular-lens-power-calculation-in-keratoconus-A-review-of-literature2019Journal-of-Current-OphthalmologyOpen-Access (1).pdf

Download (305kB) | Preview
Official URL: https://www.scopus.com/inward/record.uri?eid=2-s2....

Abstract

Purpose: To review the published literature regarding cataract surgery in keratoconus (KCN) patients with emphasis on challenges encountered during intraocular lens (IOL) power calculation and their solutions. Methods: A literature review was performed to investigate all the relevant articles on the advancements of IOL calculations in KCN patients. Results: Cataract surgery in keratoconic eyes can improve patients' refraction, and proper patient selection and IOL calculation methods are necessary to get the best results. The main problem in KCN patients is unreliable biometric measurements. It is more difficult to make conclusions in more advanced keratoconic corneas, as the steep keratometric values in these eyes will result in the selection of a low-power IOL. Presence of a low-power IOL will yield in extreme postoperative hyperopia, and IOL exchange might be mandatory. In cases in which keratoplasty may be needed in the future, contact lens fitting can help surgeons make a better decision preoperatively. Axial length (AL) measurements may have better repeatability and reproducibility than keratometry (K) readings in keratoconic eyes. SRK II formula may provide the most accurate IOL power in mild KCN. There is still not a comprehensive consensus of which formula is the best one in moderate and severe KCN, as the literature is limited in this subject. Conclusions: Various methods of IOL power calculation optimization and recommendations may hold the key to improve surgical outcomes in keratoconic eyes. There are multiple sources of biometric error in KCN patients, hence IOL calculation methods may not be as efficient as expected in these eyes. © 2019 Iranian Society of Ophthalmology

Item Type: Article
Additional Information: cited By 0
Subjects: WW Ophthalmology
Depositing User: eprints admin
Date Deposited: 19 Oct 2020 07:57
Last Modified: 19 Oct 2020 07:57
URI: http://eprints.iums.ac.ir/id/eprint/15252

Actions (login required)

View Item View Item